* Comparison with existing OMRON products.
* Comparison with existing OMRON products.
The EASY type safety light curtain well is suited for straight forward on/off detection applications.
By carefully selecting the available functions, we have reduced man hours necessary for installation by approximately 1/2 when compared with existing OMRON models.
Reduced installation time means added savings to your project's budget, start with the EASY type.
Machine safety first, narrowed down to the simplest functions:
Upon detection of personnel, the machine stops. Simple yet very optimal.
1/2 the mounting time
Fixed response time makes calculation of the safety distance is easier.
Reduced wiring, one-touch brackets and easy-to-view alignment beams all add up to cost savings.
Additionally, with one fixed response time, it is know easier to calculate the safety distance.
Global Support
OMRON will support you through the our global network
Easy-to-view Diagnostics
These indicators enable you to intuitively know the status and cause of any error.
Allowing you faster installation while reducing machine down time.
In addition to the simple functions inherited from the EASY type, such as global support, easy-to-view indicators, the BASIC type includes series connection and simple muting functions . This enables the BASIC type to satisfy installations that require multiple safety light curtains.
Up to three sets-connected in series
It is possible to connect up to three sets of safety light curtains in series. These sensors can be placed in a U-shaped or L-shaped pattern with a single power line, thus requiring less wiring.
Instant visibility of process trouble during muting
The BASIC type includes a muting function which temporarily disables the safety light curtain when a workpiece passes through. In the event of any trouble occurring, the error can be instantly recognized from the pattern of the LED indicators, allowing for a fast solution.
Functions inherited from the EASY type
Simple functions such as universal power voltage specification, easy-to-view diagnostics, a fixed response time have been inherited from the EASY type, As a result, expect reduced work-hours at each stage of use, from design and installation to operation.
The detection capability supports finger protection through use of 9 mm resolution. The ADVANCED type is equipped with various functions such as blanking, muting and the programing of warning zones. All settings can be done via an easy to use software tool. This Tool simplifies installations that were previously complicated, again our way of reducing cost and increasing productivity.
Tool for setting parameters and checking the system status
With the ADVANCED type (F3SJ-A) “SD Manager”, all parameters can be set and the system status can be checked with a personal computer. Complex settings are now simple to configure
Detection capability supports finger-protection
Even if the distance from the hazard is short, we have prepared a lineup that includes safety light curtains with a detection capability of 14 mm.
Equipped with partial muting that disables only the beams where a workpiece passes through, and position detection muting that disables the beams while detecting the position of a machine or robot.
Partial muting
Position detection muting
If a part of the mechanical equipment is within the detection zone of the Safety Light Curtain, the relevant beams can be disabled. This is possible not only with non-moving parts but also with moving parts.
Fixed blanking
Floating blanking
Under normal use, if an intrusion occurs in the safety zone, the machine will stop immediately. However, use of a warning zone will only notify the operator that an intrusion has occurred. This can be used to prevent carelessness resulting in machine stoppage on the part of the operator.
Dividing the zone between series-connected sensors
A single sensor zone can also be divided
* Sold separately
OMRON has developed "one-touch" brackets which speed mounting to aluminum framing and reduce mounting time in half, when compared with existing models.
This unique design allows for smooth horizontal movement, beam alignment is easy.
Simple positional alignment can be done using the blue LEDs at the top (TOP) and bottom (BTM) of the emitter and receiver. With the blue LEDs ON, you can see at a glance that the beams' positions are correctly aligned.
* Sold separately
Use of the laser pointer allows simple alignment of the beams especially across long distances.
This saves approximately 60% of installation time.
Light curtain status can be immediately determined as the LED will light to indicate the status or possible error.
The days of searching through user manuals to find the cause of certain muting errors are long gone. Now these errors and their causes can be well understood.
The connector can be used to easily connect between an emitter and a receiver, reducing the required wiring time by more than 50%.
Less wiring also reduces the width of the terminal block, saving valuable space in the control panel.
Note: The simple wiring connector can be used for F3SJ-A/B in auto reset mode only, not for F3SJ-E.
* Comparison with existing OMRON products.
All parameters can be set and the system status can be checked with a personal computer. In addition to making it easy to monitor the beam alignment, the ambient incident light intensity can be displayed in bar graph form for an easy check of the system status.
The incident light level can be displayed in a bar graph for each beam.
The incident light level when the light emission of the Safety Light Curtain is stopped is displayed in a bar graph.
The cause of the errors and countermeasures are both displayed.
Protects the sensor unit from direct exposure to the coolant.
The aluminum frame and transparent plate protect the sensor unit from direct exposure to the coolant. The cover protects the sensor's detection surface from collision with a workpiece, etc.
Protects the sensor from entry of the coolant that runs around the sensor.
The coolant-resistant H-NBR sponge used inside the cover protects the sensor from entry of the coolant that runs around the sensor.
Note: The sensor may be affected depending on the type of the cutting oil. Check the oil type before use.
The muting function temporarily disables the light curtain when an object must pass through the detection zone, such as when supplying a workpiece to your equipment. In the past, this function required a dedicated muting controller, but now it is built into the F3SJ. To use the muting function, purchase the Muting Key Cap (for F3SJ-B: F39-CN10 and for F3SJ-A: F39-CN6) (sold separately). The muting function is enabled simply by replacing the Unit's cap with this Key Cap. In addition, a muting sensor that determines the muting timing, as well as a muting lamp that notices the muting status to other operators, should be connected to the F3SJ.
The muting time for the F3SJ-A can be set via the software tool.
[Built-in muting function]
No controller required. Simply attach the Key Cap (sold separately) to the sensor.
With F3SJ-A, the muting function temporarily disables the Safety Light Curtain when an object must pass through the detection zone, such as when supplying a workpiece to your equipment. "Partial muting," which further heightens the level of safety, and "position detection muting," which allows muting when the safety status can be determined by the position of a machine (such as a robot), have been newly added to the muting function.
Partial muting raises safety by muting only the beams of the Safety Light Curtain in the area where the workpiece passes through, while preventing muting in all other areas.
This is used in applications where the workpiece is set in position each time by an operator, and then a turntable or positioning robot moves the workpiece to the area where the work is done. A limit switch or other means is used to detect when the robot is in a safe position, and muting is then applied.
last update: June 1, 2017
Model | PNP output | F3SJ-E[][][][]P25 |
---|---|---|
NPN output | F3SJ-E[][][][]N25 | |
Sensor type | Type 4 safety light curtain | |
Setting tool connection *1 | Parameter settings: Not available | |
Safety category | Safety purpose of category 4, 3, 2, 1, or B | |
Detection capability | Opaque objects 25 mm in diameter | |
Beam gap (P) | 20 mm | |
Number of beams (n) | 8 to 54 | |
Protective height (PH) | 185 to 1,105 mm | |
Lens diameter | Diameter 5 mm | |
Operating range *2 | 0.2 to 7 m | |
Response time
(under stable light incident condition) |
ON to OFF | 15 ms max. |
OFF to ON | 70 ms max. | |
Startup waiting time | 2 s max. | |
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | |
Consumption
current (no load) |
PNP output | Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams:
63 mA max. Receiver: Up to 22 beams: 42 mA max., 26 to 42 beams: 47 mA max., 46 to 54 beams: 51 mA max. |
NPN output | Emitter: Up to 22 beams: 41 mA max., 26 to 42 beams: 57 mA max., 46 to 54 beams:
63 mA max. Receiver: Up to 22 beams: 40 mA max., 26 to 42 beams: 45 mA max., 46 to 54 beams: 48 mA max. |
|
Light source (emitted
wavelength) |
Infrared LED (870 nm) | |
Effective aperture angle
(EAA) |
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the
detection distance is 3 m or over |
|
Safety
outputs (OSSD) |
PNP output | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
NPN output | Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
|
Output operation mode | Safety output: On when receiving light | |
Input voltage | PNP output | Test input:
ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 |
NPN output | Test input:
ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA) OFF voltage: 1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5 |
|
Mutual interference
prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | |
Test function | Self test (at power-ON and at power distribution)
External test (emission stop function by test input) |
|
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | |
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | |
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | |
Operating ambient light
intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | |
Degree of protection | IP65 (IEC 60529) | |
Vibration resistance | Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z
directions |
|
Shock resistance | Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions | |
Pollution degree | Pollution degree 3 (IEC 60664-1) | |
Power cable | Connection method: Pull-out type, cable length 3 m
Number of wires: Emitter: 5 wires, receiver: 6 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
|
Extension cable | 30 m max. *6 | |
Material | Case: Aluminum
Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
|
Weight (packed state) | Weight (g) = (protective height) x 2.6 + 800 | |
Accessories | Instruction Manual, User's Manual (CD-ROM) *7 | |
Applicable standards | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment) IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as
capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. To extend a cable of the F3SJ-E, refer to the User's Manual (SCHG-733/732).
*7. Mounting brackets and test rod are sold separately.
Nameofindicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is
receiving light. |
--- |
Stable-state
indicator |
STB | Turns ON when incidence level is more
than 170% of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is ON.
Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-E enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-E enters a
lockout on the receiver. |
Blinks when the F3SJ-E enters a lockout
on the emitter. |
Power indicator | POWER | Turns ON while the power of the
emitter is ON. |
Blinks when the F3SJ-E enters a lockout
due to power voltage/noise. |
Test indicator | TEST | --- | Blinks when external test is being
performed. |
Bottom-beam-
state indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
--- |
Nameofindicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
--- |
Stable-state
indicator |
STB | Turns ON when incidence level is more
than 170% of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is ON.
Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-E enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-E enters a
lockout on the emitter. |
Blinks when the F3SJ-E enters a lockout
on the receiver. |
Communication
indicator |
COM | Turns ON when communication between
emitter and receiver is established. |
Blinks when the F3SJ-E enters lockout
due to a communication error between receiver and emitter. |
Configuration
indicator |
CFG | --- | Blinks when the F3SJ-E enters lockout
due to a model type error between receiver and emitter. |
Internal error
indicator |
INTERNAL | --- | Blinks when the F3SJ-E enters a lockout
due to an internal error. |
Bottom-beam-
state indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
--- |
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life * | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2,
EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C, Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum, Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3),
instruction manual |
* Battery life varies depending on a battery used.
Model | PNP output | F3SJ-B[][][][]P25 |
---|---|---|
NPN output | F3SJ-B[][][][]N25 | |
Sensor type | Type 4 safety light curtain | |
Setting tool connection *1 | Parameter settings: Not available | |
Safety category | Safety purpose of category 4, 3, 2, 1, or B | |
Detection capability | Opaque objects 25mm in diameter | |
Beam gap (P) | 20 mm | |
Number of beams (n) | 8 to 102 | |
Protective height (PH) | 185 to 2,065 mm | |
Lens diameter | Diameter 5 mm | |
Operating range *2 | 0.2 to 7 m | |
Response time
(under stable light incident condition) |
ON to OFF | 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) |
OFF to ON | 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | |
Startup waiting time | 2 s max. | |
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | |
Consumption
current (no load) |
PNP output | Emitter: Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75
mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. Receiver: Up to 22 beams: 45 mA max., 26 to 42 beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max. |
NPN output | Emitter: Up to 22 beams: 52 mA max., 26 to 42 beams: 68 mA max., 46 to 62 beams: 75
mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. Receiver: Up to 22 beams: 47 mA max., 26 to 42 beams: 52 mA max., 46 to 62 beams: 58 mA max., 66 to 82 beams: 63 mA max., 86 to 102 beams: 69 mA max. |
|
Light source (emitted
wavelength) |
Infrared LED (870 nm) | |
Effective aperture angle
(EAA) |
Based on IEC 61496-2.Within +/-2.5° for both emitter and receiver when the detection
distance is 3 m or over |
|
Safety outputs
(OSSD) |
PNP output | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
NPN output | Two NPN transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
|
Auxiliary
output |
PNP output | One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), leak current 1 mA max. |
NPN output | One NPN transistor outputs, load current 100 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), leak current 1 mA max. |
|
Output operation mode | Safety output: On when receiving light
Auxiliary output: - Reverse output of safety output for a basic system - ON when muting/override for a muting system |
|
Input voltage | PNP output | Test input, Interlock select input, Reset input, Muting input:
ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5, OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5, OFF voltage: open |
NPN output | Test input, Interlock select input, Reset input, Muting input:
ON voltage: 0 to 3 V (short circuit current: approx. 4.0 mA), OFF voltage:1/2 Vs to Vs or open (short circuit current: approx. 3.0 mA) *5 External device monitoring input: ON voltage: 0 to 3 V (short circuit current: approx. 5.5 mA) *5, OFF voltage: open |
|
Mutual interference
prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | |
Series connection | Time division emission by series connection
• Number of connections: up to 3 sets (between F3SJ-Bs only)Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39- JBR2W) and power cable) |
|
Test function | • Self test (at power-ON and at power distribution)
• External test (emission stop function by test input) |
|
Safety-related functions | • Interlock (basic system)
• External device monitoring (basic system) • Muting (muting system) • Override (muting system) |
|
Connection type | Connector method (M12, 8-pin) | |
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | |
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | |
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | |
Operating ambient light
intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | |
Insulation resistance | 20 MΩ min. (at 500 VDC) | |
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | |
Degree of protection | IP65 (IEC 60529) | |
Vibration resistance | Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z
directions |
|
Shock resistance | Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions | |
Pollution degree | Pollution degree 3 (IEC 60664-1) | |
Power cable | Connection method: Prewired connector cable, cable length 0.3 m, connector type
(M12, 8-pin), connector: IP67 rated (when mated) Number of wires: 8 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
|
Extension cable | 30 m max. | |
Material | Case: Aluminum
Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
|
Weight (packed state) | Weight (g) = (protective height) x 2.7 + 500 | |
Accessories | Instruction Manual, User's Manual (CD-ROM) *6 | |
Applicable standards | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment) IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
*1. Do not use the Support Software and Setting Console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable load inductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as
capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. Mounting brackets are sold separately.
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks during muting/override, or when cap
error or connection error occurs. |
Stable-state
indicator |
STB | Turns ON when incidence level is more
than 170% of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout
on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter
is ON. |
Blinks when the F3SJ-B enters a lockout
due to power voltage/noise. |
Test indicator | TEST | --- | Blinks when external test is being
performed. |
Muting error
indicator |
MUTING
ERROR |
--- | Blinks during a muting error. |
Muting input 1
indicator |
MUTE1 | Turns ON when muting input 1 is ON
under the muting system. |
--- |
Muting input 2
indicator |
MUTE2 | Turns ON when muting input 2 is ON
under the muting system. |
--- |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
Blinks during muting/override. |
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks during muting/override, or when
cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is more
than 170% of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns OFF when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout
on the receiver. |
Communication
indicator |
COM | Turns ON when communication between
emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout
due to a communication error between receiver and emitter. |
Configuration
indicator |
CFG | --- | Blinks when the F3SJ-B enters lockout
due to a model type error between receiver and emitter. |
Internal error
indicator |
INTERNAL | --- | Blinks when the F3SJ-B enters a lockout
due to an internal error. |
Interlock indicator | INT-LK | Turns ON when the F3SJ-B is in interlock
state. |
Blinks when the F3SJ-B enters a lockout
due to a wiring error. |
External device
monitoring indicator |
EDM | Turns ON when an input is given to
external device monitoring input. *1 *2 |
Blinks when the F3SJ-B enters a lockout
due to an external device monitoring error. |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
Blinks during muting/override. |
*1. It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
*2. The meanings of the indicators are different for the models with the suffix "-01TS". Refer to the F3SJ-B[][][][]P25-01TS Safety Light Curtain User's Manual (SCHG-734) or the specifications of the models with the suffix "-01TS".
Model | F3SJ-B[][][][]P25-01TS | F3SJ-B[][][][]P25-02TS | |
---|---|---|---|
Sensor type | Type 4 safety light curtain | ||
Setting tool connection *1 | Parameter settings: Not available | ||
Safety category | Safety purpose of category 4, 3, 2, 1, or B | ||
Detection capability | Opaque objects 25mm in diameter | ||
Beam gap (P) | 20 mm | ||
Number of beams (n) | 8 to 102 | 10 to 98 | |
Protective height (PH) | 185 to 2,065 mm | 225 to 1,985 mm | |
Lens diameter | Diameter 5 mm | ||
Operating range *2 | 0.2 to 7 m *2 | 0.2 to 6 m | |
Response time
(under stable light incident condition) |
ON to OFF | 15 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | |
OFF to ON | 70 ms max. (response time at 1 set connection, series connection of 2 sets or 3 sets) | ||
Startup waiting time | 2 s max. | ||
Power supply voltage (Vs) | SELV/PELV 24 VDC±20% (ripple p-p 10% max.) | ||
Consumption
current (no load) |
Emitter | Up to 22 beams: 52 mA max., 26 to 42
beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 102 beams: 101 mA max. |
Up to 22 beams: 52 mA max., 26 to 42
beams: 68 mA max., 46 to 62 beams: 75 mA max., 66 to 82 beams: 88 mA max., 86 to 98 beams: 99 mA max. |
Receiver | Up to 22 beams: 45 mA max., 26 to 42
beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 102 beams: 67 mA max. |
Up to 22 beams: 45 mA max., 26 to 42
beams: 50 mA max., 46 to 62 beams: 56 mA max., 66 to 82 beams: 61 mA max., 86 to 98 beams: 66 mA max. |
|
Light source (emitted
wavelength) |
Infrared LED (870 nm) | ||
Effective aperture angle
(EAA) |
Based on IEC 61496-2.Within +/-2.5° for both emitter and receiver when the
detection distance is 3 m or over |
||
Safety outputs (OSSD) | Two PNP transistor outputs, load current 200 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), Leakage current 1 mA max., load inductance 2.2 H max. *3, Maximum capacity load 1 μF *4 |
||
Auxiliary output | One PNP transistor outputs, load current 100 mA max., residual voltage 2 V max.
(except for voltage drop due to cable extension), leak current 1 mA max. |
||
Output operation mode | Safety output: On when receiving light
Auxiliary output: Reverse output of safety output |
Safety output: On when receiving light
Auxiliary output: • Basic system Reverse output of safety output • Muting system On during muting/override |
|
Input voltage | Test input
ON voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 OFF voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 Reset input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5 OFF voltage: open |
Test input, Interlock select input, Reset
input, Muting input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 3.0 mA) *5 OFF voltage: 0 V to 1/2 Vs or open (short circuit current: approx. 4.0 mA) *5 External device monitoring input: ON voltage: Vs-3 V to Vs (short circuit current: approx. 6.0 mA) *5 OFF voltage: open |
|
Mutual interference
prevention function |
Mutual interference prevention algorithm prevents interference in up to 3 sets. | ||
Series connection | Time division emission by series
connection • Number of connections: up to 3 sets (between F3SJ-B[][][][]P25-01TSs only) Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39-JBR2W) and power cable) |
Time division emission by series
connection • Number of connections: up to 3 sets (between F3SJ-B[][][][]P25-02TSs only) Other models cannot be connected. • Total number of beams: up to 192 beams • Cable length between sensors: 7 m max. (not including series connection cable (F39-JBR2W) and power cable) |
|
Test function | • Self test (at power-ON and at power distribution)
• External test (emission stop function by test input) |
||
Safety-related functions | External device monitoring | External device monitoring (basic system)
Muting (muting system) Override (muting system) |
|
Connection type | Connector method (M12, 8-pin) | ||
Protection circuit | Output short-circuit protection, and power supply reverse polarity protection | ||
Ambient temperature | Operating: -10 to 55°C (non-freezing), Storage: -25 to 70°C | ||
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% RH | ||
Operating ambient light
intensity |
Incandescent lamp: 3,000 lx max., Sunlight: 10,000 lx max. | ||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||
Dielectric strength | 1,000 VAC 50/60 Hz, 1 min | ||
Degree of protection | IP65 (IEC 60529) | ||
Vibration resistance | Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z
directions |
||
Shock resistance | Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions | ||
Pollution degree | Pollution degree 3 (IEC 60664-1) | ||
Power cable | Connection method: Prewired connector cable, cable length 0.3 m, connector type
(M12, 8-pin), connector: IP67 rated (when mated) Number of wires: 8 wires Cable diameter: Dia. 6 mm Allowable bending radius: R5 mm |
||
Extension cable | 30 m max. | ||
Material | Case: Aluminum
Cap: ABS resin, PBT Optical cover: PMMA resin (acrylic) Cable: Oil resistant PVC |
||
Weight (packed state) | Weight (g) = (protective height) x 2.7 + 500 | Weight (g) = (protective height) x 2.9 + 550 | |
Accessories | User's Manual (CD-ROM), Instruction Manual *6 | ||
Applicable standards | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective
Equipment) IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
Note: 1. The test input logic of the models with the suffix "-01TS" is inverted. Refer to the F3SJ-B[][][][]P25-01TS safety
light curtain user'smanual (SCHG-734) for details.
2. Reset mode is fixed with auto reset mode.
*1. Do not use the support software and setting console for F3SJ-A. Operation cannot be guaranteed.
*2. Use of the Spatter Protection Cover causes a 10% maximum sensing distance attenuation.
*3. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the
safety output at 4 Hz or less, the usable loadinductance becomes larger.
*4. These values must be taken into consideration when connecting elements including a capacitive load such as
capacitor.
*5. The Vs indicates a voltage value in your environment.
*6. Mounting brackets and test rod are sold separately.
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks when cap error or connection error
occurs. |
Stable-state
indicator |
STB | Turns ON when incidence level is 170% or
more of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout
on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter
is ON. |
Blinks when the F3SJ-B enters a lockout
due to power voltage/noise. |
Test indicator | TEST | --- | Blinks when external test is being
performed. |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
--- |
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks when cap error or connection error
occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170%
or more of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout
on the receiver. |
Communication
indicator |
COM | Turns ON when communication between
emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout
due to a communication error between receiver and emitter. |
Configuration
indicator |
CFG | --- | Blinks when the F3SJ-B enters lockout
due to a model type error between receiver and emitter. |
Internal error
indicator |
INTERNAL | --- | Blinks when the F3SJ-B enters a lockout
due to an internal error. |
Interlock indicator | INT-LK | Not used | Not used |
External device
monitoring indicator |
EDM | Turns ON when an input is given to
external device monitoring input. * |
Blinks when the F3SJ-B enters a lockout
due to an external device monitoring error. |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
--- |
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks during muting/override, or when
cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170%
or more of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the receiver. |
Blinks when the F3SJ-B enters a lockout
on the emitter. |
Power indicator | POWER | Turns ON while the power of the emitter
is ON. |
Blinks when the F3SJ-B enters a lockout
due to power voltage/noise. |
Test indicator | TEST | --- | Blinks when external test is being
performed. |
Muting error indicator | MUTING
ERROR |
--- | Blinks during a muting error. |
Muting input 1
indicator |
MUTE1 | Turns ON when muting input 1 is ON
under the muting system. |
--- |
Muting input 2
indicator |
MUTE2 | Turns ON when muting input 2 is ON
under the muting system. |
--- |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
Blinks during muting/override. |
Name of indicator | Label | ON | Blinking |
---|---|---|---|
Top-beam-state
indicator |
TOP | Turns ON when the top beam is receiving
light. |
Blinks during muting/override, or when
cap error or connection error occurs. |
Stable-state indicator | STB | Turns ON when incidence level is 170%
or more of the output ON threshold. |
Blinks when the safety output is turned
OFF due to disturbance light or vibration. |
ON/OFF-state
indicator |
ON
OFF |
Green: Turns ON when safety output is
ON. Red: Turns ON when safety output is OFF. |
Red: Blinks when the F3SJ-B enters a
lockout due to a safety output error. |
Lockout indicator | LOCKOUT | Turns ON when the F3SJ-B enters a
lockout on the emitter. |
Blinks when the F3SJ-B enters a lockout
on the receiver. |
Communication
indicator |
COM | Turns ON when communication between
emitter and receiver is established. |
Blinks when the F3SJ-B enters lockout
due to a communication error between receiver and emitter. |
Configuration
indicator |
CFG | --- | Blinks when the F3SJ-B enters lockout
due to a model type error between receiver and emitter. |
Internal error
indicator |
INTERNAL | --- | Blinks when the F3SJ-B enters a lockout
due to an internal error. |
Interlock indicator | INT-LK | Not used | Not used |
External device
monitoring indicator |
EDM | Turns ON when an input is given to
external device monitoring input. * |
Blinks when the F3SJ-B enters a lockout
due to an external device monitoring error. |
Bottom-beam-state
indicator |
BTM | Turns ON when the bottom beam is
receiving light. |
Blinks during muting/override. |
* It turns ON when there is an external device monitoring input regardless of the availability of the external device monitoring.
Model | F3SP-B1P | |
---|---|---|
Applicable sensor | F3SJ-B/A (Only for PNP output type) * | |
Power supply voltage | 24 VDC±10% | |
Power consumption | DC1.7 W max. (not including sensor's current consumption) | |
Operation time | 100 ms max. (not including sensor's response time) | |
Response time | 100 ms max. (not including sensor's response time) | |
Relay output | Number of contacts | 3NO+1NC |
Rated load | 25 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms | |
Rated current | 5 A | |
Connection type | Between sensors | M12 connector (8-pin) |
Others | Terminal block | |
Weight (packed state) | Approx. 280 g | |
Accessories | Instruction manual |
* NPN output type cannot be connected. Also, the system cannot be used as a muting system.
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series *1 |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life *2 | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2,
EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3),
instruction manual |
*1. It cannot be mounted to the models with the suffix "-02TS".
*2. Battery life varies depending on a battery used.
Model | PNP
outputs |
F3SJ-A[][][][]P14 | F3SJ-A[][][][]P20 | F3SJ-A[][][][]P30 | F3SJ-A[][][][]P55 |
---|---|---|---|---|---|
NPN
outputs |
F3SJ-A[][][][]N14 | F3SJ-A[][][][]N20 | F3SJ-A[][][][]N30 | F3SJ-A[][][][]N55 | |
Sensor type | Type 4 safety light curtain | ||||
Version | Ver. 2 | ||||
Setting tool connection | Connectable | ||||
Safety category | Safety purpose of category 4, 3, 2, 1, or B | ||||
Detection capability | Opaque objects
14 mm in diameter |
Opaque objects
20 mm in diameter |
Opaque objects
30 mm in diameter |
Opaque objects
55 mm in diameter |
|
Beam gap (P) | 9 mm | 15 mm | 25 mm | 50 mm | |
Number of beams (n) | 26 to 140 | 16 to 100 | 10 to 100 | 6 to 50 | |
Protective height (PH) | 245 to 1,271 mm | 245 to 1,505 mm | 245 to 2,495 mm | 270 to 2,470 mm | |
Lens diameter | Diameter 5 mm | ||||
Operating range * | 0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.)
(Depending on the setting tool, the detection distance can be shortened to 0.5 m.) |
||||
Response
time (under stable light incident condition) (For details, see "Response Time" on Catalog.) |
ON to OFF | 1 set,
0245 to 983: 11 ms to 17.5 ms max. 1,055 or higher: 20 ms to 25 ms max. |
1 set,
0245 to 1205: 10 ms to 15 ms max. 1235 or higher: 17.5 ms to 22.5 ms max. |
1 set: 10 ms to
17.5 ms max. |
1 set: 10 ms to
13 ms max. |
OFF to ON | 1 set,
0245 to 983: 44 ms to 70 ms max. 1,055 or higher: 80 ms to 100 ms max. |
1 set,
0245 to 1205: 40 ms to 60 ms max. 1235 or higher: 70 ms to 90 ms max. |
1 set: 40 ms to
70 ms max. |
1 set: 40 ms to
52 ms max. |
|
Startup waiting time | 2 s max. (2.2 s max. for series connection) | ||||
Power supply voltage (Vs) | 24 VDC ±20% (ripple p-p10% max.) | ||||
Current
consumption (no load) |
Emitter | To 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA
max., 151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max. |
|||
Receiver | To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA
max., 151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max. |
||||
Light source (emitted
wavelength) |
Infrared LED (870 nm) | ||||
Effective aperture angle
(EAA) |
Based on IEC 61496-2. Within ±2.5° for both emitter and receiver when the detection
distance is 3 m or over |
||||
Safety
outputs (OSSD) |
PNP
outputs |
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), allowable capacity load 2.2 μF, leak current 1 mA max. (This can be different from traditional logic (ON/OFF) because safety circuit is used.) |
|||
NPN
Output |
Two NPN transistor outputs, load current 300 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), allowable capacity load 2.2 μF, leak current 2 mA max. (This can be different from traditional logic (ON/OFF) because safety circuit is used.) |
||||
Auxiliary
output 1 (Non-safety output) |
PNP
outputs |
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), leak current 1 mA max. |
|||
NPN
Output |
One NPN transistor output, load current 300 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), leak current 1 mA max. |
||||
Auxiliary
output 2 (Non-safety output. Function for Basic System.) |
PNP
outputs |
One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), leak current 1 mA max. |
|||
NPN
Output |
One NPN transistor output, load current 50 mA max., residual voltage 2 V max. (except
for voltage drop due to cable extension), leak current 1 mA max. |
||||
External indicator output
(Non-safety output) |
Available indicators
• Incandescent lamp: 24 VDC, 3 to 7 W • LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max. (To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.) |
||||
Output
operation mode |
Receiver | Safety output 1, 2: ON when receiving light
Auxiliary output 1: Inverse of safety output signals (Operation mode can be changed with the setting tool.) External indicator output 1: Inverse of safety output signals for a basic system (Operation mode can be changed with the setting tool.), ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
|||
Emitter | Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached
(Operation mode can be changed with the setting tool.) External indicator output 2: ON when lock-out for a basic system (Operation mode can be changed with the setting tool.) ON when muting/override for a muting system (Operation mode can be changed with the setting tool.) |
||||
Input
voltage |
PNP
output |
Test input, Interlock select input, Reset input, Muting input:
ON voltage: 9 V to Vs (short circuit current: approx. 2.0 mA), OFF voltage: 0 to 1.5 V, or open External device monitoring input: ON voltage: 9 V to Vs (short circuit current: approx. 3.5 mA), OFF voltage:open Note: The Vs indicates a voltage value in your environment. |
|||
NPN
output |
Test input, Interlock select input, Reset input, Muting input:
ON voltage: 0 to 1.5 V (short-circuit current: approx. 1.5 mA), OFF voltage: 9 V to Vs, or open External device monitoring input: ON voltage: 0 to 1.5 V (short-circuit current: approx. 4.0 mA), OFF voltage:open Note: The Vs indicates a voltage value in your environment. |
||||
Indicator | Emitter | Light intensity level indicators (green LED x 2, orange LED x 3): ON based on the light
intensity Error mode indicators (red LED x 3): Blink to indicate error details Power indicator (green LED x 1): ON while power is on Interlock indicator (yellow LED x 1): ON while under interlock, blinks at lockout. External device monitoring indicator (muting input 1 indicator), Blanking/test indicator (muting input 2 indicator) (green LED x 2): ON/flash according to function |
|||
Receiver | Light intensity level indicators (green LED x 2, orange LED x 3): ON based on the light
intensity Error mode indicators (red LED x 3): Blink to indicate error details OFF output indicator (red LED x 1): ON when safety output is OFF, blinks at lockout. ON output indicator (green LED x 1): ON while safety output is ON Muting error indicator, Blanking /test indicator (green LED x 2): ON/flash according to function |
||||
Mutual interference
prevention function |
Interference light prevention algorithm, detection distance change function | ||||
Series connection | Time division emission by series connection
• Number of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected. • Total number of beams: up to 400 beams • Cable length between sensors: 15 m max. (not including series connection cable (F39-JJR3W or F39-JJR[]L) and power cable) • Response time under connection: Refer to Catalog |
||||
Test function | • Self test (at power-ON and at power distribution)
• External test (emission stop function by test input) |
||||
Safety-related functions | • Start interlock, restart interlock (Must be set with a setting tool when the muting
function is used.) • External device monitor • Muting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.) • Fixed blanking (must be set by a setting tool) • Floating blanking (must be set by a setting tool) |
||||
Connection method | Connector method (M12, 8-pin) | ||||
Protective circuits | Output short-circuit protection, and power supply reverse polarity protection | ||||
Ambient temperature | Operating: -10 to 55°C (no icing), Storage: -30 to 70°C | ||||
Ambient humidity | Operating: 35% to 85% (no condensation), Storage: 35% to 95% | ||||
Operating ambient light
intensity |
Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving-
surface light intensity of 10,000 lx max. |
||||
Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
Withstand voltage | 1,000 VAC 50/60 Hz, 1 min | ||||
Degree of protection | IP65 (IEC 60529) | ||||
Vibration resistance | Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions | ||||
Shock resistance | Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions | ||||
Materials | Casing (including metal parts on both ends): Aluminum, zinc die-cast
Cap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC |
||||
Weight (packed state) | Calculate using the following expressions:
(1) For F3SJ-A[][][][]14, weight (g) = (protective height) x 1.7 + α (2) For F3SJ-A[][][][]20/F3SJ-A[][][][]25/F3SJ-A[][][][]30, weight (g) = (protective height) x 1.5 + α (3) For F3SJ-A[][][][]55, weight (g) = (protective height) x 1.4 + α The values for α are as follows: Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400 Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600 Protected height 1,136 to 1,658 mm: = 2,000 |
||||
Accessories | Instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom
mounting), mounting brackets (intermediate) (*), error mode label, User's Manual (CD-ROM) * Number of intermediate brackets depends on protective height of F3SJ. • For protective height from 600 to 1,130 mm: 1 set for each of the emitter and receiver is included • For protective height from 1,136 to 1,658 mm: 2 sets for each of the emitter and receiver are included • For protective height from 1,660 to 2,180 mm: 3 sets for each of the emitter and receiver are included • For protective height from 2,195 to 2,500 mm: 4 sets for each of the emitter and receiver are included |
||||
Applicable standards | IEC 61496-1, EN 61496-1, UL 61496-1, Type 4 ESPE (Electro-Sensitive protective
equipment)
IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic protective devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3 ISO 13849-1: 2015, EN ISO 13849-1: 2015 (PLe/Safety Category 4) UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8 |
Model | Protected Height
(mm) |
Number of Beams | Response time ms
(ON to OFF) |
Response time ms
(OFF to ON) |
---|---|---|---|---|
F3SJ-A[]14 Series | 245 to 263 | 26 to 28 | 11 | 44 |
281 to 389 | 30 to 42 | 12 | 48 | |
407 to 497 | 44 to 54 | 13 | 52 | |
515 to 605 | 56 to 66 | 14 | 56 | |
623 to 731 | 68 to 80 | 15 | 60 | |
767 to 983 | 84 to 108 | 17.5 | 70 | |
1,055 to 1,271 | 116 to 140 | 20 | 80 | |
F3SJ-A[]20 Series | 245 | 16 | 10 | 40 |
275 to 425 | 18 to 28 | 11 | 44 | |
455 to 635 | 30 to 42 | 12 | 48 | |
665 to 815 | 44 to 54 | 13 | 52 | |
845 to 995 | 56 to 66 | 14 | 56 | |
1,025 to 1,205 | 68 to 80 | 15 | 60 | |
1,235 to 1,505 | 82 to 100 | 17.5 | 70 | |
F3SJ-A[]30 Series | 245 to 395 | 10 to 16 | 10 | 40 |
420 to 720 | 17 to 29 | 11 | 44 | |
745 to 1,045 | 30 to 42 | 12 | 48 | |
1,070 to 1,295 | 43 to 52 | 13 | 52 | |
1,395 to 1,620 | 56 to 65 | 14 | 56 | |
1,745 to 1,995 | 70 to 80 | 15 | 60 | |
2,120 to 2,495 | 85 to 100 | 17.5 | 70 | |
F3SJ-A[]55 Series | 270 to 770 | 6 to 16 | 10 | 40 |
820 to 1,420 | 17 to 29 | 11 | 44 | |
1,470 to 2,070 | 30 to 42 | 12 | 48 | |
2,120 to 2,470 | 43 to 50 | 13 | 52 |
Note:
Use the following expressions for series connection.
For 2-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit - 1 (ms), Response time (OFF
to ON): Response time calculated by the above x 4 (ms)
For 3-set series connection:
Response time (ON to OFF):
Response time of the 1st unit + Response time of the 2nd unit + Response time of 3rd unit - 5 (ms), Response time (OFF
to ON): Response time calculated by the above x 5 (ms)
(For models with the "-TS" suffix, multiply the response time obtained by the above x 5 (ms), or use 200 ms, whichever
is less.)
For 4-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit + Response time of the 3rd
unit + Response time of the 4th unit - 8 (ms)
Response time (OFF to ON): Response time calculated by the above x 5 (ms)
Total cable extension length must be no greater than the lengths described below.
Condition | 1 set | 2 sets | 3 sets | 4 sets |
---|---|---|---|---|
Using incandescent lamp for auxiliary output and external indicator output | 45 m | 40 m | 30 m | 20 m |
Not using incandescent lamp * | 100 m | 60 m | 45 m | 30 m |
Condition | 1 set | 2 sets | 3 sets | 4 sets |
---|---|---|---|---|
Using incandescent lamp for external indicator output 2 | 40 m | 30 m | 25 m | 20 m |
Using incandescent lamp for external indicator output 1 | 60 m | 45 m | 30 m | 20 m |
Using incandescent lamp for auxiliary output 1 | ||||
Not using incandescent lamp * | 100 m | 60 m | 45 m | 30 m |
Note: Keep the cable length within the rated length. Failure to do so is dangerous as it may prevent safety functions from
operating normally.
* The F39-A01P[]-PAC Dedicated External Indicator Set uses LEDs. Refer to the cable extension lengths for "Not using
incandescent lamp".
Model | F3SP-B1P | |
---|---|---|
Applicable sensor | F3SJ-B/A (Only for PNP output type) * | |
Power supply voltage | 24 VDC±10% | |
Power consumption | DC1.7 W max. (not including sensor's current consumption) | |
Operation time | 100 ms max. (not including sensor's response time) | |
Response time | 10 ms max. (not including sensor's response time) | |
Relay output | Number of contacts | 3NO+1NC |
Rated load | 25 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms | |
Rated current | 5 A | |
Connection type | Between sensors | M12 connector (8-pin) |
Others | Terminal block | |
Weight (packed state) | Approx. 280 g | |
Accessories | Instruction manual |
* NPN output type cannot be connected. Also, the system cannot be used as a muting system.
Model | F39-PTJ |
---|---|
Applicable sensor | F3SJ Series |
Power supply voltage | 4.65 or 4.5 VDC |
Battery | Three button batteries (SR44 or LR44) |
Battery life * | SR44: 10 hours of continuous operation, LR44: 6 hours of continuous operation |
Light source | Red semiconductor laser (wavelength: 650 nm, 1 mW max. JIS class 2,
EN/IEC class 2, FDA class II) |
Spot diameter (typical value) | 6.5 mm at 10 m |
Ambient temperature | Operating: 0 to 40°C Storage: -15 to 60°C (with no icing or condensation) |
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) |
Material | Laser module case: aluminum Mounting bracket: aluminum and stainless |
Weight | Approx. 220 g (packed) |
Accessories | Laser safety standard labels (EN: 1, FDA: 3) Button batteries (SR44: 3),
instruction manual |
* Battery life varies depending on a battery used.
Model | F39-A01PR-PAC | F39-A01PG-PAC | F39-A01PY-PAC |
---|---|---|---|
Applicable sensor | F3SJ-A (Common for PNP/NPN output type. Can be attached to emitters and/or receivers) | ||
Light source | Red LED | Green LED | Yellow LED |
Power supply voltage | 24 VDC±10% (supplied by sensor) | ||
Consumption current | 50 mA max. (supplied by sensor) | ||
Connection type | Dedicated accessory connector cable (Sensor side: Dedicated 10-pin connector,
Indicator side: M12 8-pin connector) |
||
Set details | Indicator (red),
Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Indicator (green),
Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Indicator (yellow),
Dedicated connector cable (0.1 m), Dedicated mounting bracket (1 for each) |
Model | F39-EJ[][][][]-L, F39-EJ[][][][]-D | |
---|---|---|
Applicable sensor | F3SJ-A Series Curtains with a protective
height of 600 mm or shorter. |
F3SJ-A Series Curtains with a protective
height of 605 mm or longer. |
Ambient temperature | -10 to 55°C ( operation and storage ) | 13 to 33°C ( operation and storage ) |
Mounting direction | No restrictions | Vertical direction only (see following diagram) |
Operating range | 0.2 to 7 m (for a protective height of 1,631 mm max.), 0.2 to 5 m (for a protective height
of 1,655 mm min.) |
|
Degree of protection | IP67 (IEC 60529) (When assembled according to the application precautions) | |
Material | Case: Acrylic resin, Rubber: Nitrile rubber, M5 bolt: SUSXM7, M4 bolt: SUS316L,
Cable: Oil-resistant PVC, Plate: SUS304, Mounting Bracket (optional): SUS304 |
|
Weight (packed state) | Calculation formula: Weight (g) = 1.5 x [][][][] + 300 ([][][][] stands for the four digits of the
model number (protective height)) (The optional Mounting Brackets come in a set of two, and weigh 120 g. This weight is not included in the above formula.) |
Note: 1. Vibration
When using Curtains with a protective height of 605 mm or more, the vibration performance of the applicable
sensor is reduced.
Do not use these Curtains in locations that are subject to vibration.
2. Operating range
When using these cases, the operating range of the applicable sensor is reduced.
Check the specifications prior to use.
3. Mounting direction
When using Curtains with a protective height of 605 mm or more,some slackness occurs due to the weight
of the Curtain.
For this reason, mount these Curtains only in the vertical direction.
last update: June 1, 2017
(Unit: mm)
The dimensions of the F3SJ-E and F3SJ-B are the same except for connector cables and cable leads.
Material: Stainless
Material : Zinc die-cast
Material : Zinc die-cast
Material : Zinc die-cast
Material : Zinc die-cast
Material : Stainless
Material : Stainless
C (protective height): 4-digit number in the Model name
A = C + 159
B = C + 86
C (protective height): 4-digit number in the Model name
A = C + 159
B = C + 86
Material: Stainless
C (protective height): 4-digit number in the Model name
A = C + 69
B = C + 47.5
D = C - 45
C (protective height): 4-digit number in the Model name
A = C + 69
B = C + 47.5
D = C - 45
Material: Stainless
Note: 1. The protective height of the F3SJ-E/B series that supports the contact mount bracket is limited.
Protective height allowed for mounting: 185 mm to 1,105 mm (225 mm to 545 mm for the model with the
suffix "-02TS")
2. Brackets of other models such as F39-LJB1 cannot be used simultaneously.
The number of the brackets needed for the F3SJ-B[][][][]P25-02TS differs from the other F3SJ-E/B series. The table below shows the number of brackets corresponding to the protective heights.
Cable color: Gray for emitter and Black for receiver
* Cables with L=3, 7, 10, 15, and 20 m are available.
Cable color: Gray for emitter and Black for receiver
L = [][][][] - 21 mm
Material: PC (protective cover)
Material: Stainless steel
Material: Brass
Material: Stainless steel
* Use F = 350 or less when none of the F values shown above are used.
When only F39-LJ3 free-location mounting brackets are used without standard brackets, allow a space of at least 350 mm between the brackets. The number of brackets required varies according to the protective height. For details about the number of required brackets, refer to the table below.
The standard included intermediate brackets are the same as the F39-LJ3 free-location mounting brackets. Purchase brackets as necessary if there are fewer intermediate brackets than required. When intermediate brackets are included, they can be used as free-location mounting brackets.
Note: Refer to the User's Manual for the dimensions for side mounting.
* Using M5 bolt, available range for mounting is 18 to 20
To check available brackets for replacement, refer to the table below.
To check dimensions when mounting brackets, refer to Catalog.
The values in the table correspond to in the model name, meaning the protective height (mm) of a sensor.
For backside mounting, the F3SJ-A and F3SJ-E/B can be used without modification due to compatibility in mounting hole pitch. For side mounting, a new hole needs to be made due to the different mounting hole pitch.
Dimensional drawing of mounting hole for side mounting using intermediate bracket
Single-Ended Cable
F39-JD3A (L = 3 m)
F39-JD7A (L = 7 m)
F39-JD10A (L = 10 m)
F39-JD15A (L = 15 m)
F39-JD20A (L = 20 m)
Cable color: Gray for emitter Black for receiver
* Cables with L=3, 7, 10, 15, and 20 m are available.
Double-Ended Cable
F39-JDR5B (L = 0.5 m)
F39-JD1B (L = 1 m)
F39-JD3B (L = 3 m)
F39-JD5B (L = 5 m)
F39-JD7B (L = 7 m)
F39-JD10B (L = 10 m)
F39-JD15B (L = 15 m)
F39-JD20B (L = 20 m)
Cable color: Gray for emitter Black for receiver
Material: Stainless steel
Material: PC (transparent area), ABS (non-transparent area)
* The four intermediate brackets (F39-PJ-MS) for side mounting are not provided.
*The Mounting Brackets (F39-EJ-R) are sold separately.
*The Mounting Brackets (F39-EJ-S) are sold separately.