For the best durability in the Food & Beverage industry
For the best durability in the Food & Beverage industry
Proven with various industrial detergents of Ecolab and Diversey
- Withstands heat shock conditions(IP68)
- Epoxy resin preventing water ingress if connector is not fixed properly
- Compact size and shape
- High grade steel housing(SUS316L)
High power red LED for max. sensing performance and & easy alignment
Model Item |
Sensing Method | Through-beam | Retro-Reflective with MSR function | |
---|---|---|---|---|
NPN output | Pre-wired | E3FC-TN11 2M | E3FC-RN11 2M | |
M12 Connector | E3FC-TN21 | E3FC-RN21 | ||
PNP output | Pre-wired | E3FC-TP11 2M | E3FC-RP11 2M | |
M12 Connector | E3FC-TP21 | E3FC-RP21 | ||
Sensing distance | 20m |
0.1 to 4 m (with E39-R1S) |
||
Spot diameter | - | |||
Standard sensing object | Opaque: 7 mm dia.min. | Opaque: 75 mm dia.min. | ||
Differential travel | - | |||
Directional angle | 2° min. | |||
Light source (wavelength) | Red LED (624 nm) | Red LED (624 nm) | ||
Power supply voltage | 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) | |||
Current consumption |
40 mA max. (Emitter 25 mA max. Receiver 15 mA max.) |
25 mA max. | ||
Control output |
NPN/PNP (open collector) Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. |
|||
Operation mode | Light-ON/Dark-ON selectable by wiring *1. | |||
Indicator |
Operation indicator (orange) Stability indicator (green) Power indicator (green): only Emitter of Through-beam |
|||
Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection | |||
Response time | 0.5 ms | |||
Sensitivity adjustment | Fixed | |||
Ambient Illumination (Reciever side) | Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max. | |||
Ambient temperature range | Operating: -25 to 55°C/ Storage: -30 to 70°C (with no icing or condensation) | |||
Ambient humidity range | Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation) | |||
Insulation resistance | 20 MΩ min. at 500 VDC | |||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions | |||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions | |||
Degree of protection | IEC: IP67, IP68 *2., DIN 40050-9: IP69K *3. | |||
Weight | Pre-wired cable (2M) | 152 g | 76 g | |
Connector | 44 g | 22 g | ||
Material | Case | SUS 316L (1.4404) | ||
Lens and Display | PMMA | |||
Adjuster | - | |||
Nut | SUS 316L (1.4404) | |||
Accessories |
Instruction sheet M18 nuts (4 pcs) |
Instruction sheet M18 nuts (2 pcs) |
Model Item |
Sensing Method | Diffuse-reflective | ||||
---|---|---|---|---|---|---|
NPN output | Pre-wired | E3FC-DN12 2M | E3FC-DN13 2M | E3FC-DN15 2M | E3FC-DN16 2M | |
M12 Connector | E3FC-DN22 | E3FC-DN23 | E3FC-DN25 | E3FC-DN26 | ||
PNP output | Pre-wired | E3FC-DP12 2M | E3FC-DP13 2M | E3FC-DP15 2M | E3FC-DP16 2M | |
M12 Connector | E3FC-DP22 | E3FC-DP23 | E3FC-DP25 | E3FC-DP26 | ||
Sensing distance |
300 mm (white paper:300 x 300 mm) |
1 m (white paper: 300 x 300 mm) |
300 mm (white paper: 300 x 300 mm) |
1 m (white paper: 300 x 300 mm) |
||
Spot diameter (reference value) |
40 x 50 mm Sensing distance of 300 mm |
120 x 150 mm Sensing distance of 1 m |
40 x 50 mm Sensing distance of 300 mm |
120 x 150 mm Sensing distance of 1 m |
||
Standard sensing object | - | |||||
Differential travel | 20% max. | |||||
Directional angle | - | |||||
Light source (wavelength) | Red LED (624 nm) | Infrared LED (850 nm) | ||||
Power supply voltage | 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) | |||||
Current consumption | 25 mA max. | |||||
Control output |
NPN/PNP (open collector) Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. |
|||||
Operation mode | Light-ON/Dark-ON selectable by wiring *3. | |||||
Indicator |
Operation indicator (orange) Stability indicator (green) |
|||||
Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection | |||||
Response time | 0.5 ms | |||||
Sensitivity adjustment | One-turn adjuster | |||||
Ambient Illumination | Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max. | |||||
Ambient temperature range | Operating: -25 to 55°C/ Storage: -30 to 70°C (with no icing or condensation) | |||||
Ambient humidity range | Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation) | |||||
Insulation resistance | 20 MΩ min. at 500 VDC | |||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case | |||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions | |||||
Shock resistance | Destruction: 500 m/s*2 3 times each in X, Y and Z directions | |||||
Degree of protection | IEC: IP67, IP68 *2., DIN 40050-9: IP69K *3. | |||||
Weight | Pre-wired cable (2M) | 76 g | ||||
Connector | 22 g | |||||
Material | Case | SUS 316L (1.4404) | ||||
Lens and Display | PMMA | |||||
Adjuster | POM | |||||
Nut | SUS 316L (1.4404) | |||||
Accessories |
Instruction sheet M18 nuts (2 pcs) |
Model Item |
Sensing Method | BGS (Background suppression ) | Transparent detected with P-opaquing function | ||
---|---|---|---|---|---|
NPN output | Pre-wired | E3FC-LN11 2M | E3FC-LN12 2M | E3FC-BN11 2M | |
M12 Connector | E3FC-LN21 | E3FC-LN22 | E3FC-BN21 | ||
PNP output | Pre-wired | E3FC-LP11 2M | E3FC-LP12 2M | E3FC-BP11 2M | |
M12 Connector | E3FC-LP21 | E3FC-LP22 | E3FC-BP21 | ||
Sensing distance |
100 mm (white paper: 300 x 300 mm) |
200 mm (white paper: 300 x 300 mm) |
100 to 500 mm (with E39-RP1) |
||
Spot diameter (reference value) |
10 x 10 mm Sensing distance of 100 mm |
10 x 15 mm Sensing distance of 200 mm |
- | ||
Standard sensing object | - | glass (t = 1.0 mm): 150 × 150 mm | |||
Differential travel | 20% max. | - | |||
Directional angle | - | ||||
Light source (wavelength) | Red LED (624 nm) | ||||
Power supply voltage | 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) | ||||
Current consumption | 25 mA max. | ||||
Control output |
NPN/PNP (open collector) Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. |
||||
Operation mode | Light-ON/Dark-ON selectable by wiring *1. | ||||
Indicator |
Operation indicator (orange) Stability indicator (green) |
||||
Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection | ||||
Response time | 0.5 ms | ||||
Sensitivity adjustment | Fixed | One-turn adjuster | |||
Ambient Illumination | Incandescent lamp: 3,000 lx max./ Sunlight: 10,000 lx max. | ||||
Ambient temperature range | Operating: -25 to 55°C/ Storage: -30 to 70°C(with no icing or condensation) | ||||
Ambient humidity range | Operating: 35 to 85%/ Storage: 35 to 95% (with no condensation) | ||||
Insulation resistance | 20 MΩ min. at 500 VDC | ||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case | ||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z directions | ||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions | ||||
Degree of protection | IEC: IP67, IP68 *2., DIN 40050-9: IP69K *3. | IEC: IP67, DIN 40050-9: IP69K *3 | |||
Weight | Pre-wired cable (2M) | 76 g | Approx. 95 g/Approx. 65 g | ||
Connector | 22 g | Approx. 50 g/Approx. 20 g | |||
Material | Case | SUS 316L (1.4404) | |||
Lens and Display | PMMA | ||||
Adjuster | - | POM | |||
Nut | SUS 316L (1.4404) | ||||
Accessories |
Instruction sheet M18 nuts (2 pcs) |
E3FC-T[]
E3FC-R[]
E3FC-D[]2
E3FC-D[]3
E3FC-D[]5
E3FC-D[]6
E3FC-L[]1, E3FC-L[]2
E3FC-B[]1
E3FC-T[]
E3FC-R[]
E3FC-D[]2
E3FC-D[]3
E3FC-D[]5
E3FC-D[]6
E3FC-B[]1
E3FC-L[]1
E3FC-L[]2
Operation mode |
Timing charts |
Operation selector |
Output circuit |
---|---|---|---|
Light-ON |
|
Connect the pink wire Pin(2)) to the brown (Pin(1)) |
Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models
|
Dark-ON |
|
Connect the pink wire (Pin(2)) to the blue (Pin(3)) or open the pink wire (Pin(2)) |
|
|
Operation mode |
Timing charts |
Operation selector |
Output circuit |
---|---|---|---|
Light-ON |
|
Connect the pink wire (Pin(2)) to the brown (Pin(1)) |
Background suppression |
Dark-ON |
|
Connect the pink wire (Pin(2)) to the blue (Pin(3)) or open the pink wire (Pin(2)) |
Operation mode |
Timing charts |
Operation selector |
Output circuit |
---|---|---|---|
Light-ON |
|
Connect the pink wire (Pin(2)) to the brown (Pin(1)) or open the pink wire (Pin(2)) |
Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models |
Dark-ON |
|
Connect the pink wire (Pin(2)) to the blue (Pin(3)) |
|
|
Operation mode |
Timing charts |
Operation selector |
Output circuit |
---|---|---|---|
Light-ON |
|
Connect the pink wire (Pin(2)) to the brown (Pin(1)) or open the pink wire (Pin(2)) |
Background suppression |
Dark-ON |
|
Connect the pink wire (Pin(2)) to the blue (Pin(3)) |
M12 Connector Pin Arrangement
M12 4-wire Connectors
Classification | Wire color | Connector pin No. | Application |
---|---|---|---|
DC | Brown | 1 | Power supply (+V) |
White | 2 | L/on • D/on selectable | |
Blue | 3 | Power supply (0 V) | |
Black | 4 | Output |
Be sure to follow the safety precautions below for added safety.
1. Do not use the sensor under the environment with explosive, flammable or corrosive gas.
2. Do not use the sensor under the oil or chemical environment exceeding specifications. Performance is assured for typical detergents and disinfectants used in Food & Beverage industry.
Refer to the following table when using these agents:
Manufacturer | Product name |
Concen- tration |
Testtime |
---|---|---|---|
Diversey | Diverfoam SMS HD | 5% | 720 h |
Oxofoam | 5% | 720 h | |
Acifoam | 5% | 720 h | |
Divosan Hypochlorit | 1% | 720 h | |
Divosan Forte | 1% | 720 h | |
Ecolab | P3-topactive® 200 | 5% | 720 h |
P3-topax® 56 | 5% | 720 h | |
P3-topactive® OKTO | 3% | 720 h | |
P3-topax® 990 | 3% | 720 h | |
P3-topax® 66 | 3% | 720 h | |
General | H2O2 | 6,5% | 240 h |
3. Do not use the sensor under the environment under the other conditions in excess of rated.
4. Do not use the sensor in place that is exposed by direct sunlight.
5. Do not use the sensor in place where the sensor may receive direct vibration or shock.
6. Do not use the thinner, alcohol, or other organic solvents.
7. Never disassemble, repair nor tamper with the sensor.
8. Please process it as industrial waste.
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E3FC-T[]1[]
E3FC-R[]1[]
E3FC-D[]1[]
E3FC-L[]1[]
E3FC-B[]1[]
E3FC-T[]2[]
E3FC-R[]2[]
E3FC-D[]2[]
E3FC-L[]2[]
E3FC-B[]2[]
E39-R1S
E39-R50
E39-RP1
E39-R16
E39-L183
E39-EL16
TITLE | DOCUMENT TYPE | SIZE |
E98E-EN-02/E3FC Data Sheet | Catalog | 2403 KB |
---|