Field data collected and accumulated for “preventive maintenance” and “operation monitoring”.
An analysis of such field data requires high-level know-how and time, causing a burden to people
responsible for the production site management.
The Self-Monitoring Sensor manufactured by Panasonic is capable of reporting sensor data and its own state to the host device through the I/O Link master.
With the Self-Monitoring Sensor, you can immediately judge the state of the sensor and easily identify the cause of failure. Thus, this sensor contributes to the reduction of the burden experienced by the client in collecting and analyzing data.
|
|
Problems are solved by the high-level self-diagnosis.
* | By creating a program with a PLC, etc., the "State" of the self-monitoring sensor can be grasped. |
---|
Easy use of IoT
|
“Predictive maintenance” can be easily achieved through monitoring the state of the Self-Monitoring Sensor. |
Improvements to the digital display deliver a wide viewing angle along with increased clarity. The display pressure range and set pressure range have also been increased. |
Thanks to a redesign of its circuitry, power consumption of the low-power-consumption DP-100L series during normal operation has been reduced by 14%. |
To prevent from breakage due to miswiring.
Equipped with a 30 mm 1.181 in square compact-sized dual display.
The current value and the threshold value can be checked at the same time, so the threshold value can be set and checked smoothly without switching to another screen mode.
ON / OFF operations still continue while the threshold values are being set, so setting to the same sensitivity as dial control-type sensors is possible.
Key lock function is equipped as well.
|
12 segments are used and an alphanumeric display has been adopted. This improves visual checking of letters and numbers.
No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased. |
The low pressure type displays measurements in 0.1 kPa at a resolution of 1/2,000 and has a response time of 2.5 ms (variable up to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 % F.S. repeatability, giving it high performance. |
The setting levels are clearly separated into "RUN mode" for operation settings that are carried out daily, "MENU SETTING mode" for basic settings, and "PRO mode" for special and detailed setting.
These make setting operations easy to understand and easy to carry out.
|
|
|
|
|
|
If the reference pressure of the device changes, two functions are selectable. One is auto-reference function, which partially shift the comparative output judgment level by the amount that the reference pressure shifts. The other is remote zero-adjustment function, which can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are required.
Without auto-reference and remote zero-adjustment functions |
With auto-reference function applied |
With remote zero-adjustment function applied |
The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as affixing a label to the device to indicate the normal pressure value. |
The DP-100L setting details appear in the digital display. Because the settings are in numeric form that can be easily understood, it is useful such as when receiving technical support by telephone. |
The peak values and bottom values for fluctuating pressures can be displayed using the dual display.
This mode lowers the display luminance to cut power consumption by approximately 30 %. The displays can also be turned off completely to achieve a power saving of approximately 50 %.
An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available.
|
|
|
Connector attached cable (2m 6.562 ft), as an accessory, can be connected easily with one-touch connection.
|
By equipping the push-in converter with DP-10□-M(-P), pressure port can be converted from M5 female thread to Rc1/8 female thread. Bore diameter conversion to the DP2 / DP3 series is possible.
By mounting the flat attachment to DP-10□-M(-P), pressure port and cable can now be pulled out in downward, left or right directions. Flat mounting on surfaces such as the wall is made possible.
Sensor
Sensor mounting bracket (Optional)
|
|
Sensor mounting bracket (Optional)
|
|
Panel mounting bracket (Optional), Front protection cover (Optional)
|
|
Panel mounting bracket (Optional)
|
|
Conversion bushing (Optional)
|
Flat attachment (Optional)
|
Material: | Polybutylene terephthalate (PBT) (Glass fiber reinforced) (Enclosure) Stainless steel (SUS303) (Pressure port) Hydrogenated Nitrile Butadiene Rubber (H-NBR) (O-ring) |
---|---|
Weight : | 15 g approx. (flat attachment only) |
Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached.
Flat attachment (Optional)
|
Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached.
Connector attached cable (Optional, CN-14A-C2 is attached to DP-10□ZL3-M-P)
•Length L |
|
TITLE | DOCUMENT TYPE | SIZE |
FX-550L / DP-100L / HG-C1000L | Catalog | 2143 KB |
---|---|---|
DP-100L INDEX LIST | Manual | 227 KB |
DP-100L | Manual | 562 KB |