Rated voltage | Resistive load |
---|---|
125 VAC
250 VAC 30 VDC |
5 A
3 A 3 A |
last update: November 1, 2017
Rated voltage | Resistive load |
---|---|
125 VAC
250 VAC 30 VDC |
5 A
3 A 3 A |
Rated voltage | Resistive load |
---|---|
125 VAC
250 VAC 30 VDC |
1 A
0.5 A 1 A |
Rated voltage | Resistive load |
---|---|
250 VAC
30 VDC |
3 A
3 A |
Rated voltage | Resistive load |
---|---|
250 VAC
30 VDC |
0.5 A
1 A |
Certification body | Standards | File No. |
---|---|---|
UL * | UL508,
CSA C22.2 No.14 |
E76675 |
TÜV SÜD | EN60947-5-1 (certified direct opening),
EN60947-5-5 |
Consult your OMRON representative for details. |
CQC (CCC) | GB14048.5 | 2003010303070678 |
Rated voltage | Resistive load |
---|---|
125 VAC
250 VAC 30 VDC |
5 A
3 A 3 A |
Note: Minimum applicable load: 5 VDC, 150 mA
Rated voltage | Resistive load |
---|---|
125 VAC
250 VAC 30 VDC |
1 A
0.5 A 1 A |
Note: Minimum applicable load: 5 VDC, 1 mA
Rated voltage | Rated current | Operation voltage |
---|---|---|
24 VAC/VDC | 8 mA | 24 VAC/VDC±5% |
Type | Emergency Stop Switch | |||
---|---|---|---|---|
Non-lighted
A165E-S/A165E-M |
Lighted
A165E-LS/A165-LM |
Non-lighted,
One-piece construction A165E-U |
||
Allowable
operating frequency |
Mechanical | 20 operations/minute max. | ||
Electrical | 10 operations/minute max. | |||
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||
Dielectric
strength |
Between terminals
of same polarity |
1,000 VAC, 50/60 Hz for 1 min | ||
Between terminals
of different polarity |
2,000 VAC 50/60 Hz for 1 min | |||
Between each
terminal and ground |
2,000 VAC 50/60 Hz for 1 min | |||
Between lamp
terminals |
1,000 VAC, 50/60 Hz for 1 min *1 | --- | ||
Vibration
resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) | ||
Shock
resistance |
Destruction | 500 m/s2 | ||
Malfunction | 300 m/s2 max.
(malfunction within 1 ms) |
150 m/s2 max.
(malfunction within 1 ms) |
||
Durability | Mechanical | 100,000 operations min. | ||
Electrical | 100,000 operations min. | |||
Degree of protection | IP65 Oil-resistant *2 | IP65 *2 | IP65 Oil-resistant *2 | |
Electric shock protection class | Class II | |||
PTI (tracking characteristic) | 175 | |||
Degree of contamination | 3 (EN60947-5-1) | |||
Weight | Approx. 16 g (in case of 2NC(2) Switches) | |||
Ambient operating temperature | -10 to 55°C (with no icing or condensation) | |||
Ambient operating humidity | 35% to 85% | |||
Ambient storage temperature | -25 to 65°C (with no icing or condensation) |
*1. LED not mounted. (Test them with the LED removed.)
*2. Degree of protection from the front of the panel.
Type | Characteristics of models
with separate construction |
Characteristics of models
with one-piece construction |
---|---|---|
Operating force OF max. | 14.7 N | 14.7 N |
Releasing torque RF max. | 0.1 Nm | 0.1 Nm |
Pretravel PT | 3.5±0.5 mm | 3±0.5 mm |
last update: November 1, 2017
last update: November 1, 2017
(Unit: mm)
Non-lighted,
One-piece construction models 30 mm diameter
Non-lighted models
40 mm diameter
Lighted models
40 mm diameter
One-piece construction models
40 mm diameter
Select an appropriate Panel Plug according to the panel design and mount from the front side of the panel. Panel cutout dimensions are the same as those for the Operation Unit.
Note: The L+ and L− terminals are not available with the non-lighted models.
last update: November 1, 2017
TITLE | DOCUMENT TYPE | SIZE |
A165E | Catalogue | 2965 KB |
---|