Model |
E2EQ-X4X1 E2EQ-X4X1-M1(T)J |
E2EQ-X8X1 E2EQ-X8X1-M1(T)J |
E2EQ-X15X1 E2EQ-X15X1-M1(T)J |
|
---|---|---|---|---|
Sensing distance | 4 mm ±10% | 8 mm ±10% | 15 mm ±10% | |
Set distance *1 | 0 to 3.2 mm | 0 to 6.4 mm | 0 to 12 mm | |
Differential travel | 15% max. of sensing distance | |||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | |
Response frequency *2 | 1 kHz | 0.5 kHz | 0.25 kHz | |
Control output | Load current | 3 to 100 mA | ||
Residual voltage *3 | 5 V max. (Load current: 100 mA, Cable length: 2 m) | |||
Operation mode (with sensing object approaching) |
Load ON: NO; For details, refer to the timing charts on Data Sheet. | |||
Protection circuits | Load short-circuit protection, Surge suppressor | |||
Ambient temperature range | Operating: -25 to 70°C Storage: -40 to 85°C (with no icing or condensation) |
|||
Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
||
Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Shock resistance | Destruction: 1,000m/s2 10 times each in X, Y, and Z directions | |||
Connection method | Pre-wired Models (Standard cable length: 2 m) Pre-wired Connector Models |
|||
Weight (packed state) |
Pre-wired Models | Approx. 65 g | Approx. 140 g | Approx. 190 g |
Pre-wired Connector Models |
Approx. 20 g | Approx. 40 g | Approx. 90 g |
Note:Use the Sensor within the range in which the green indicator is ON.
Note:The response frequency is an average value.
Note:The residual voltage is 5 V. Make sure that the device connected to the Sensor can withstand the residual voltage.
Model |
E2EQ-X3D1 E2EQ-X3D1-M1(T)GJ |
E2EQ-X7D1 E2EQ-X7D1-M1(T)GJ |
E2EQ-X10D1 E2EQ-X10D1-M1(T)GJ |
|
---|---|---|---|---|
Sensing distance | 3 mm ±10% | 7 mm ±10% | 10 mm ±10% | |
Set distance | 0 to 2.4 mm | 0 to 5.6 mm | 0 to 8 mm | |
Differential travel | 10% max. of sensing distance | |||
Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | |
Response frequency * | 1 kHz | 500 Hz | 400 Hz | |
Control output | Load current | 3 to 100 mA | ||
Residual voltage | 3 V max. (Load current: 100 mA, Cable length: 2 m) | |||
Operation mode (with sensing object approaching) |
Load ON: NO; For details, refer to the timing charts on Data Sheet. | |||
Protection circuits | Load short-circuit protection, Surge suppressor | |||
Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | |||
Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
Voltage influence | ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
Shock resistance | Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions | |||
Connection method | E2EQ-X@D1: Pre-wired Models (Standard cable length: 2 m) E2EQ-X@D1-M1GJ: Pre-wired Connector Models (Standard cable length: 300mm) |
|||
Weight (packed state) |
Pre-wired Models | Approx. 120 g | Approx. 160 g | Approx. 220 g |
Pre-wired Connector Models |
Approx. 80 g | Approx. 110 g | Approx. 190 g |
Note:The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
Model |
E2EQ-X4X1 E2EQ-X4X1-M1(T)J E2EQ-X3D1 E2EQ-X3D1-M1(T)GJ |
E2EQ-X8X1 E2EQ-X8X1-M1(T)J E2EQ-X7D1 E2EQ-X7D1-M1(T)GJ |
E2EQ-X15X1 E2EQ-X15X1-M1(T)J E2EQ-X10D1 E2EQ-X10D1-M1(T)GJ |
|
---|---|---|---|---|
Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Data Sheet.) |
|||
Power supply voltage (operating voltage range) |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. | |||
Leakage current | 0.8 mA max. | |||
Indicators | Operation indicator (red), Setting indicator (green) | |||
Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | |||
Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
Dielectric strength | 1,000 VAC for 1 min between current-carrying parts and case | |||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
Degree of protection | IEC 60529 IP67, in-house standards: oil-resistant | |||
Materials | Case | Fluororesin coating (Base material: brass) | ||
Sensing surface | Fluororesin | |||
Clamping nuts | Fluororesin coating (Base material: brass) | |||
Toothed washer | Zinc-plated iron | |||
Accessories | Instruction manual |
last update: September 24, 2012
Note:Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
TITLE | DOCUMENT TYPE | SIZE |
E2EQ Data Sheet | Data Sheet | 822 KB |
---|---|---|
E2EQ Proximity Switch Instruction Sheet (ENG/JPN) |
Manual | 1070 KB |
E2EQ Proximity Sensor Instruction Sheet (ENG/JPN/ITA/GER/FRE/SPA) |
Manual | 1396 KB |
E2E[]-XD/XT/XE/XF/XC/XB/CC/CB Proximity Sensor Instruction Sheet (ENG/JPN/ITA/GER/FRE/SPA) |
Manual | 4703 KB |