Compact Industrial SCARA
Compact Industrial Robot with light weight space saving arm. Its high speed operation is best suited for pick and place, labelling, tracking
• Certified by UL, CSA, and VDE (models numbers with a suffix of “-VD”).
• Socket type, same size as LY Power Relays.
• Operation indicator provided to confirm input (models numbers with “N” before the suffix).
Model | Rated voltage | Operating voltage | Impedance | Voltage level | |
---|---|---|---|---|---|
Must operate voltage |
Must release voltage |
||||
G3H-203SN-VD | 5 to 24 VDC | 4 to 28 VDC |
15 mA max. (See note 2.) |
4 VDC max. | 1 VDC min. |
G3H-203SLN-VD | 5 VDC | 4 to 6 VDC | 390 Ω±20% | 4 VDC max. | 1 VDC min. |
12 VDC | 9.6 to 14.4 VDC | 900 Ω±20% | 9.6 VDC max. | ||
24 VDC | 19.2 to 28.8 VDC | 2 kΩ±20% | 19.2 VDC max. | ||
G3HD-X03SN-VD | 5 to 24 VDC | 4 to 28 VDC |
1.5 kΩ +20%/-10%
(See note 1.) |
4 VDC max. | 1 VDC min. |
G3H-203S-VD | 4 to 24 VDC | 3 to 28 VDC |
15 mA max. (See note 2.) |
3 VDC max. | 1 VDC min. |
G3H-203SL-VD | 5 VDC | 4 to 6 VDC | 390 Ω±20% | 4 VDC max. | 1 VDC min. |
12 VDC | 9.6 to 14.4 VDC | 900 Ω±20% | 9.6 VDC max. | ||
24 VDC | 19.2 to 28.8 VDC | 2 kΩ±20% | 19.2 VDC max. | ||
G3HD-X03S-VD | 4 to 24 VDC | 3 to 28 VDC |
1.5 kΩ +20%/-10%
(See note 1.) |
3 VDC max. | 1 VDC min. |
G3HD-202SN-VD | 12 to 24 VDC | 9.6 to 28.8 VDC |
25 mA max. (at 24 VDC) (See note 2.) |
9.6 VDC max. | 1 VDC min. |
Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for Solid State Relays.
2. With constant current input system.
Model | Applicable load | |||
---|---|---|---|---|
Rated load voltage | Load voltage range | Load current | Inrush current | |
G3H-203SN-VD G3H-203S-VD |
100 to 240 VAC | 75 to 264 VAC | 0.1 to 3 A at 40°C | 45 A 60 Hz, 1 cycle |
G3H-203SLN-VD G3H-203SL-VD |
||||
G3HD-X03SN-VD G3HD-X03S-VD |
4 to 48 VDC | 3 to 52.8 VDC | 0.1 to 3 A at 40°C | 18 A (10 ms) |
G3HD-202SN-VD | 24 to 240 VDC | 19.2 to 264 VDC | 0.001 to 2.5 A at 40°C | 20 A (10 ms) |
Model |
G3H-203SN-VD/ 203S-VD |
G3H-203SLN-VD/ 203SL-VD |
G3HD-X03SN-VD/ X03S-VD |
G3HD-202SN-VD |
---|---|---|---|---|
Operate time |
1/2 cycle of load power source + 1 ms max. |
1 ms max. | 0.5 ms max. | 5 ms max. |
Release time | 1/2 cycle of load power source + 1 ms max. | 2 ms max. | 10 ms max. | |
Output ON voltage drop |
1.6 V (RMS) max. |
3 V max. (output ON- resistance: 1.25 Ω max.) |
||
Leakage current |
5 mA max. (at 100 VAC); 10 mA max. (at 200 VAC) |
2.5 mA max. (at 100 VAC); 5 mA max. (at 200 VAC) |
5 mA max. (at 50 VDC) | 0.1 mA max. (at 200 VDC) |
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min | 1,500 VAC, 50/60 Hz for 1 min | ||
Vibration resistance | Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude | |||
Shock resistance | Destruction: 1,000 m/s2 | |||
Ambient temperature |
Operating: -30°C to 80°C (with no icing) Storage: -30°C to 100°C (with no icing) |
|||
Ambient humidity | 45% to 85% | |||
Certified standards |
G3H: UL508, CSA C22.2 No. 14, EN60947-4-3 G3HD: UL508, CSA C22.2 No. 14, EN60950-1 |
|||
EMC |
Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 |
|||
Weight | Approx. 50 g |
TITLE | DOCUMENT TYPE | SIZE |
G3H, G3HD | Catalog | 465 KB |
---|---|---|
Solid State Relays | Manual | 2370 KB |
Relay Defects Causes & Solutions (SSR Edition) | Technical Guide | 6806 KB |